Showing posts with label Firetube Boilers. Show all posts
Showing posts with label Firetube Boilers. Show all posts

The advantages of a packaged boiler are:

The advantages of a packaged boiler are:




1. lower freight costs because of less handling
2. lower initial cost because they are mass produced
3. quality control is easier to implement
4. the boilers can be factory tested before being sent to the customer
5. it requires little time to put the unit into operation at the plant site



a) 1, 3
b) 2, 5
c) 2, 3, 4
d) 1, 2, 3, 4, 5
e) 2, 3, 4, 5





Answer: D

A firetube boiler is one which has

A firetube boiler is one which has



a) water on the inside of the tubes and the hot gas of combustion on the outside.
b) the furnace as the first pass of the burner flame.
c) water on the outside of the tubes and hot water on the inside of the tubes.
d) water on the outside of the tubes and the hot gas on the inside of the tubes.
e) internally fired tubes surrounded by water.






Answer: D

In a packaged firetube boiler the flue gas velocity within the unit is maintained by

In a packaged firetube boiler the flue gas velocity within the unit is maintained by



a) increasing forced draft fan speed
b) constructing a taller stack
c) varying the firetube lengths
d) varying the total cross-sectional area of the fire tubes in each pass
e) decreasing forced draft fan speed





Answer: D

The wetback Scotch boiler was designed primarily for

The wetback Scotch boiler was designed primarily for



a) building heating service
b) marine service
c) traction engine service
d) railway service
e) very high capacity electrical generation





Answer: B

A major disadvantage of a firebox is

A major disadvantage of a firebox is




a) first cost is relatively high
b) it has a low heat transfer efficiency
c) it is not very compact
d) cleaning and inspection can be difficult
e) it has only one flue gas pass





Answer: D

With regard to a steam boiler, the lettering "HRT" means

With regard to a steam boiler, the lettering "HRT" means



a) highly regulated temperature
b) hot return tubes
c) horizontal return tubular
d) highly regulated treatment
e) horizontal receiver tubes





Answer: C