Showing posts with label Power Engineering Chapter 98. Show all posts
Showing posts with label Power Engineering Chapter 98. Show all posts

An air separator should always be installed in

An air separator should always be installed in




a) a horizontal pipe
b) a cross tee
c) a vertical pipe
d) an expansion tank
e) a converter





Answer: A

Diverter fittings are used in the supply lines to heating units

Diverter fittings are used in the supply lines to heating units





a) to compensate for a low heating load
b) when a higher heating output is required from the heating unit
c) when the distance from the boiler to heating unit is short
d) when there are no balancing valves installed in the supply line
e) when a hydraulic balance must be corrected




Answer: B

Snow melting systems are usually filled with

Snow melting systems are usually filled with





a) water only
b) methanol and water
c) ethylene glycol and water
d) steam
e) warm air




Answer: C

In radiant heating system changes are

In radiant heating system changes are




a) difficult to make
b) easy to make
c) as easy to make as in any other heating system
d) dependent on availability of materials
e) dependent on location





Answer: A

The system which allows the highest water temperature is the:

The system which allows the highest water temperature is the:




a. Ice melt system
b. Radiant panel system
c. Closed expansion tank system
d. Open expansion tank system
e. Reverse return system






Answer: C

One of the disadvantages of the gravity hot water system is:

One of the disadvantages of the gravity hot water system is:




a. The water temperature must be very high to compensate for heat losses
b. Piping used must be rated for high temperature services
c. There is a slow response to changes in heat demand
d. The maximum water temperature is limited to approximately 100°C
e. High maintenance




Answer: C

Advantages of the high temperature hot water systems are:

Advantages of the high temperature hot water systems are:



a. Reduction in pipe size and greater heat storage capacity
b. Low water make-up and better temperature control
c. High vacuum in the return lines and pumps
d. Higher make-up and better chemical control
e. High-pressure piping and controls





Answer: A

Automatic snow melting systems do not use:

Automatic snow melting systems do not use:




a. Hot water and antifreeze mixtures
b. Electric resistance heating
c. Infrared lamps mounted above sidewalks and ramps
d. Hot water and ethylene glycol mixed
e. Forced air heat





Answer: E

Which of the following is NOT a hydronic heating system?

Which of the following is NOT a hydronic heating system?





a. Loop system
b. One pipe system
c. Two pipe direct return system
d. Two pipe reverse return system
e. A wet-return system






Answer: E