The piping and heating units of a steam heating system must be so arranged that

The piping and heating units of a steam heating system must be so arranged that



a) the condensate can flow freely to the heating units
b) the air can be kept at the top of the heating units
c) steam can flow freely to all heating units
d) all of the above
e) none of the above





Answer: C

The two pipe gravity return steam heating system, now obsolete, had the disadvantage that during startup, some steam could pass through a radiator without condensing and could enter other radiators via the return main, thus trapping:

The two pipe gravity return steam heating system, now obsolete, had the disadvantage that during startup, some steam could pass through a radiator without condensing and could enter other radiators via the return main, thus trapping:





a. Water in the center
b. Steam in the center
c. Condensate in the center
d. Debris in the center
e. Air in the center





Answer: E

In a gravity return system, the boiler should be placed:

In a gravity return system, the boiler should be placed:




a. Well above the highest radiator
b. Well below the lowest radiator
c. On an elevated platform
d. At the same level as the radiators
e. In a central location





Answer: B

After a steam heating system has been operating for some time, you notice that some parts of the heating system are still cold. Which one of the following could be the cause of this?

After a steam heating system has been operating for some time, you notice that some parts of the heating system are still cold. Which one of the following could be the cause of this?



a. Air is trapped in the affected sections
b. Boiler water pressure too low
c. Boiler water temperature too low
d. Steam does not contain enough heat
e. Condensate temperature too low




Answer: A

The piping and heating units of a steam heating system must be so arranged that the:

The piping and heating units of a steam heating system must be so arranged that the:




a. Condensate can be circulated back to the heating units
b. Steam can flow freely from the heating units and be returned to the boiler
c. Air can be expelled from the heating units and piping
d. Air can be kept on top of the heating units
e. Condensate can flow freely to the heating units





Answer: C

When a single main is used to carry both the steam supply from the boiler to the radiators and the steam condensate from the radiators back to the boiler, the system is called a one pipe:

When a single main is used to carry both the steam supply from the boiler to the radiators and the steam condensate from the radiators back to the boiler, the system is called a one pipe:




a. Condensate return system
b. Gravity return system
c. Return trap system
d. Vacuum pump system
e. Variable vacuum system




Answer: B

All supply and drain lines of a steam heating system must be pitched to:

All supply and drain lines of a steam heating system must be pitched to:




a. Allow for drainage of condensate
b. Allow collection of air at the highest points
c. Prevent corrosion
d. Allow for thermal expansion
e. Allow steam to rise to the system high points.





Answer: A

The Hartford Loop prevents the water in the boiler from:

The Hartford Loop prevents the water in the boiler from:




a. Exceeding the maximum temperature
b. Exceeding the highest safe level
c. Dropping below a safe level
d. Entering the equalizer piping
e. Flowing out through the steam main





Answer: C