Showing posts with label Drum Internals. Show all posts
Showing posts with label Drum Internals. Show all posts

The chemical injection line is located

The chemical injection line is located




a) near the normal water level
b) close to the CBD line
c) in the steam space
d) near the internal feed pipe
e) close to the riser tubes






Answer: D

Chemicals are injected into the boiler to

Chemicals are injected into the boiler to



a) prevent corrosion
b) keep sludge dispersed
c) prevent sludge
d) prevent scale
e) all the above





Answer: E

The CBD valve is usually a

The CBD valve is usually a



a) gate valve with a metering device
b) ball valve with a metering device
c) stop/check valve with a metering device
d) butterfly valve with a metering device
e) needle valve with a metering device






Answer: E

Relative to steam drum internals, a boiler water test is conducted to

Relative to steam drum internals, a boiler water test is conducted to



a) ensure scrubbers have not corroded away
b) adjust or set the continuous blowdown valve (CBD)
c) ensure the water is not attacking the separators
d) inform us when maintenance is required on drum equipment
e) ensure chemicals are entering the boiler





Answer: B