When cooling down a steam boiler that has been taken out of service, a vent valve on the steam drum should be opened to

When cooling down a steam boiler that has been taken out of service, a vent valve on the steam drum should be opened to



a) prevent a vacuum from forming in the boiler
b) release the air from the boiler
c) purge the shell of impure gases
d) let the operator know when the pressure has reached zero
e) prevent pressure build-up in the boiler





Answer: A

On boiler cool-down the vent should be opened

On boiler cool-down the vent should be opened



a) as soon as the post-purge is completed
b) when all temperatures are at ambient value
c) any time after the NRV is closed
d) just before the unit goes into a vacuum
e) at no time





Answer: D

Before removing a boiler from service for maintenance purposes it is beneficial to

Before removing a boiler from service for maintenance purposes it is beneficial to




a) inform the Chief Inspector
b) do as little as possible with the waterside of the unit
c) use sootblowers and clean the fireside well
d) force cool the unit with post-purge air
e) drain the unit before the water cools to ambient temperature





Answer: C

While a boiler is warming up it is good practice to

While a boiler is warming up it is good practice to



a) leave all drain valves closed
b) check the low water fuel cut-off device for proper operation
c) test the safety valve before any pressure develops
d) not interfere in any way with the combustion process
e) go through a sootblowing operation sequence




Answer: B