Showing posts with label Power Engineering Chapter 74. Show all posts
Showing posts with label Power Engineering Chapter 74. Show all posts

If a pump is running and has no discharge pressure, what will you do?

If a pump is running and has no discharge pressure, what will you do?




a) close the suction valve a little
b) open the lubrication valve
c) check the lubricant level
d) check to see if the suction valve is open
e) close the discharge valve




Answer: D

If pump speed is too high

If pump speed is too high



a) the driver may be overloaded
b) discharge pressure will be below normal
c) no liquid will be delivered
d) the pump will lose its prime after starting
e) there will be air or gas in the liquid





Answer: A

A plugged impeller symptom or result will be

A plugged impeller symptom or result will be




a) air leaks in suction line and stuffing boxes
b) wrong direction of rotation
c) loss of prime
d) an overheated stuffing box
e) no liquid being delivered




Answer: E

If the packing gland of a centrifugal water pump is leaking too much, you should

If the packing gland of a centrifugal water pump is leaking too much, you should




a) tighten up the gland until all leakage has been stopped
b) tighten up the gland but permit a slight amount of leakage
c) tighten up the gland as far as is possible
d) throttle the suction valve a little
e) tighten up the gland until there is 10% leakage





Answer: B